MOBY vacuum circuit breakers are engineered for heavy-duty primary distribution networks, industrial substations, and critical manufacturing continuous operations. Manufactured with high-dielectric vacuum interrupters, our VCB units provide arc-quenching within half a cycle, eliminating fire hazards and drastically reducing contact erosion for 30,000+ mechanical switching cycles.

Rated Voltage 6.6 kV / 12 kV / 36 kV
Rated Normal Current 400A / 630A / 800A / 1250A / 2000A
Short-Circuit Breaking Up to 40 kA for 3 Seconds
Installation Type Indoor Drawout / Outdoor Kiosk
✓ 100% Factory Routine Tested ✓ Custom Ratings Built-to-Order ✓ ISO 9001:2008 Certified

Comprehensive Technical Specifications

Detailed parameter ratings, insulation limits, standards compliance, and fabrication tolerances engineered for VCB (Vacuum Circuit Breaker).

Technical Parameter Engineering Specification Compliance Standard / Condition
🔷 General Electrical Parameters
Rated Nominal System Voltage 3.3 kV / 6.6 kV / 11 kV / 33 kV IS / IEC 62271-100
Highest System Voltage 3.6 kV / 7.2 kV / 12 kV / 36 kV IEC 62271-1
Rated Continuous Current 400A / 630A / 800A / 1250A / 1600A / 2000A IS 13118
Rated Frequency 50 Hz ± 3% National Grid Standard
Number of Phases / Poles 3-Phase, 3-Pole Gang Operated Standard Specification
Rated Symmetrical Breaking Current 25 kA / 26.3 kA / 31.5 kA / 40 kA rms CPRI Type Tested
Rated Making Current (Peak) 62.5 kA / 66 kA / 78.75 kA / 100 kA peak IEC 62271-100
Short-Time Withstand Duration 3 Seconds (Standard) IS 13118
Operating Sequence O - 0.3s - CO - 3min - CO Standard Auto-Reclose
🔷 Dielectric Insulation Levels
Rated Lightning Impulse Withstand (BIL) 75 kVp (12kV) / 170 kVp (36kV) IEC 60071-1
One-Minute Power Frequency Withstand 28 kV rms (12kV) / 70 kV rms (36kV) IS 13118
Insulation Medium Air insulated cubicle with Vacuum Interrupter bottle Hermetically Sealed
Arc Quenching Medium High-vacuum bottle (< 10⁻⁷ mbar) Zero Gas Emission
🔷 Mechanical & Operational Data
Operating Mechanism Motorized Spring-Charged / Manual Spring Close & Trip Stored Energy Type
Spring Charging Motor Voltage 24V / 30V / 110V / 220V DC or 230V AC Field Selectable
Shunt Trip / Closing Coil Voltage 24V / 30V / 110V / 220V DC Standard Tripping
Mechanical Endurance Class M2 Class (> 10,000 Operations without maintenance) IEC 62271-100
Electrical Endurance Class E2 Class (Extended electrical endurance without restrike) IEC 62271-100
Degree of Enclosure Protection IP4X (Indoor Cubicle) / IP55 (Outdoor Kiosk) IS / IEC 60529
🔷 Cubicle & Constructional Details
Enclosure Sheet Thickness 2.0 mm CRCA Frame / 2.5 mm Load-Bearing Structure IS 513
Surface Treatment 7-Tank Pretreatment & Electrostatic Pure Polyester Powder Coat RAL 7032 / 7035
Busbar Material Electrolytic Grade E91E Aluminium or 99.9% ETP Copper IS 5082 / IS 613
Interlocks Comprehensive Mechanical & Electrical Safety Interlocks Fail-Safe Design
Cubicle Configurations 1 Incomer + 2 Outgoing / Bus Coupler / Single Incomer Tailored to Layout

Key Engineering & Operational Features

Why electrical consultants, industrial plants, and utility engineers specify MOBY VCB (Vacuum Circuit Breaker).

⚡

Rapid Arc Extinction

Vacuum interrupter contacts separate and quench the arc inside half an electrical cycle with virtually zero contact erosion and no toxic SF6 greenhouse gases.

🛡️

Fail-Safe Interlocking

Strict mechanical and electrical interlocks prevent racking in/out when breaker is closed, door opening when energized, and earthing under live line.

🔄

Effortless Cassette Drawout

Breaker truck features robust lead-screw rack-in mechanism with clear Test, Service, and Disconnected positions indicated both mechanically and via microswitches.

⚙️

High Mechanical Endurance

Tested to M2 mechanical endurance standards exceeding 10,000 operating cycles without recalibration, providing 25+ years of dependable industrial service life.

📊

Integrated Protection & Metering

Pre-wired for numerical overcurrent, earth fault, differential relays, and Class 0.2S multi-function digital meters with SCADA Modbus output.

🏢

Compact Indoor Footprint

High-density sheet steel fabrication allows multi-tier or ultra-compact cubicle arrangements, minimizing expensive substation civil engineering footprint.

Certified Quality & Factory Testing Standards

⚡ CPRI Tested & Approved

Every VCB (Vacuum Circuit Breaker) is manufactured under strict ISO 9001:2008 quality control protocols and subjected to comprehensive routine testing at our Kolkata facility before dispatch.

✔ CPRI / ERDA certified type test reports for short-circuit breaking and short-time withstand up to 40 kA for 3 seconds.
✔ Full lightning impulse withstand (BIL) and power frequency voltage withstand dielectric testing.
✔ Temperature rise test at rated full load current verifying busbar and contact temperatures within IS 13118 limits.
✔ Internal arc classification (IAC AFLR 25kA/1s) ensuring complete safety for operating personnel on all four sides.
✔ Routine factory acceptance testing (FAT): contact resistance measurement, opening/closing timing tests, and insulation resistance checks.

Target Industrial Sectors & Deployment Scenarios

Engineered and tested for severe continuous operational duty across diverse sectors:

🏭 Heavy Industrial Substations 🏭 Steel Rolling & Smelting Mills 🏭 Cement & Fertilizer Plants 🏭 High-Rise Commercial Towers 🏭 Utility Grid Transmission & Distribution 🏭 Solar & Wind Renewable Parks 🏭 Data Centers & Critical Hospitals

Related Switchgears & Equipment

Explore complementary electrical power distribution and protection units manufactured by Moby.

Frequently Asked Questions

Authoritative engineering answers regarding voltage ratings, CPRI testing, custom SLD fabrication, and warranty for VCB (Vacuum Circuit Breaker).

What are the technical voltage and breaking ratings for MOBY VCB (Vacuum Circuit Breaker)? +

Primary Parameter Ratings: MOBY VCB (Vacuum Circuit Breaker) is engineered for rated voltage 6.6 kV / 12 kV / 36 kV and rated normal current 400A / 630A / 800A / 1250A / 2000A. It is built to withstand prospective short-circuit breaking currents up to 40 kA for 3 seconds, fully adhering to national and international power engineering guidelines.

Is MOBY VCB (Vacuum Circuit Breaker) CPRI tested and certified? +

Certification & Type Testing: Yes, MOBY VCB (Vacuum Circuit Breaker) is CPRI Tested & Approved. All switchgears undergo comprehensive type-testing at the Central Power Research Institute (CPRI) and are routine tested (high-voltage dielectric withstand, contact resistance, and operational timing) at our ISO 9001:2008 certified Kolkata manufacturing facility prior to customer dispatch.

Can this equipment be customized according to our single-line diagram (SLD)? +

Custom Engineering Capabilities: Yes, Moby Electrotech specializes in custom-engineered electrical switchgear systems. Our Kolkata engineering team customizes incoming/outgoing feeder arrangements, CT/PT ratios, numerical protection relays, busbar ratings, enclosure dimensions, and ingress protection (IP42 to IP55) to match your exact site layout and SLD.

What is the standard warranty and quotation timeline for VCB (Vacuum Circuit Breaker)? +

Commercial Terms & Warranty: All MOBY equipment carries an engineering equipment warranty of 12 months from commissioning or 18 months from delivery. Technical commercial quotations are typically provided within 24 to 48 hours following single-line diagram (SLD) review.

Request Technical Quote for VCB (Vacuum Circuit Breaker)

Our senior electrical engineering team will review your single-line diagram (SLD), system voltage, and breaking requirements to provide a competitive quotation within 24 hours.

⚡ Direct Factory Response • Confidential Single-Line Diagram Reviews