Transformers (Power Distribution Transformers)

Oil-Cooled & Cast Resin Dry-Type Energy-Efficient Transformers

MOBY Power Distribution Transformers are engineered for optimal electrical efficiency, low no-load losses, and superior thermal withstand capacity. Available in capacities from 100 kVA up to 2000 kVA, in both oil-immersed ONAN and Cast Resin Dry-Type designs, our transformers utilize prime-grade Cold Rolled Grain Oriented (CRGO) silicon steel cores and electrolytic copper/aluminium windings to ensure 30+ years of dependable power delivery.

Capacity Range 100 kVA to 2000 kVA
Primary Voltage 11 kV / 22 kV / 33 kV
Cooling Medium Oil Immersed (ONAN) / Dry Cast Resin (AN)
Tap Changer Off-Circuit Tap Switch / On-Load Tap Changer (OLTC)
βœ“ 100% Factory Routine Tested βœ“ Custom Ratings Built-to-Order βœ“ ISO 9001:2008 Certified

Comprehensive Technical Specifications

Detailed parameter ratings, insulation limits, standards compliance, and fabrication tolerances engineered for Transformers (Power Distribution Transformers).

Technical Parameter Engineering Specification Compliance Standard / Condition
πŸ”· Electrical & Rating Parameters
Rated Power Capacity 100, 160, 250, 315, 400, 500, 630, 750, 1000, 1250, 1600, 2000 kVA Standard Ratings
Primary High Voltage (HV) 6.6 kV / 11 kV / 22 kV / 33 kV IS 2026 / IEC 60076
Secondary Low Voltage (LV) 415 V / 433 V AC (Phase-to-Phase), 250 V (Phase-to-Neutral) Standard 3-Phase 4-Wire
Rated Frequency 50 Hz Β± 3% National Grid Standard
Number of Phases / Vector Group 3-Phase, Dyn11 (Delta High Voltage / Star Low Voltage with Neutral) Standard Vector Group
Percentage Impedance (%Z) 4.5% to 5.0% for <= 630 kVA / 5.0% to 6.25% for > 630 kVA IS 1180
Energy Loss Compliance BEE Star Labeling / IS 1180 (Part-1) Energy Consumption Levels 1, 2, or 3 Maximum Efficiency
πŸ”· Core, Winding & Insulation System
Core Material High-permeability low-loss Cold Rolled Grain Oriented (CRGO) M4 / MOH silicon steel Mitred Joint Core
Winding Conductor Electrolytic Grade ETP Copper (99.9% conductivity) or EC Grade Aluminium with Nomex / Kraft paper insulation IS 613 / IS 5082
Insulating Fluid (Oil Type) Inhibited / Uninhibited Transformer Mineral Oil conforming to IS 335 / IEC 60296 Dielectric BDV > 60kV
Dry Type Insulation (Dry Type) Class F (155Β°C) or Class H (180Β°C) Vacuum Pressure Impregnated (VPI) / Cast Resin Non-Flammable
Tap Changer Mechanism Off-Circuit Tap Switch (OCTC) Β± 5% in 2.5% steps or On-Load Tap Changer (OLTC) with RTCC panel Voltage Regulation
πŸ”· Standard Fittings & Protective Accessories
Gas / Oil Surge Protection Double-float Buchholz Relay with Alarm & Trip contacts (for ratings >= 1000 kVA) IS 3637
Pressure Relief Device Spring-loaded Pressure Relief Valve (PRD) with visual indicator & trip switch Prevents Tank Rupture
Temperature Monitoring Dial-type Oil Temperature Indicator (OTI) & Winding Temperature Indicator (WTI) with microswitches With Max Pointer
Oil Level Indication Magnetic Oil Level Gauge (MOG) with low oil level electrical alarm contact Direct Sight Glass
Breather Unit Silica Gel Dehydrating Breather with oil seal to eliminate ambient moisture intake Maintains Oil BDV
Terminations Cable End Box (HV/LV) or Outdoor Glazed Porcelain Bushings Flexible Connection

Key Engineering & Operational Features

Why electrical consultants, industrial plants, and utility engineers specify MOBY Transformers (Power Distribution Transformers).

⚑

Ultra-Low Losses (IS 1180 Compliant)

Step-lap mitered core construction with prime CRGO silicon steel minimizes no-load core hysteresis and eddy-current losses, delivering peak energy efficiency.

πŸ›‘οΈ

Superior Short-Circuit Withstand

Rigidly clamped disc and helical winding construction engineered and verified to withstand mechanical forces of symmetrical and asymmetrical external short-circuits.

πŸŽ›οΈ

Automated On-Load Tap Changing (OLTC)

Optional motorized OLTC with Remote Tap Changer Control (RTCC) and Automatic Voltage Regulating (AVR) maintains constant 415V secondary voltage despite grid fluctuations.

πŸ”₯

Zero Fire Risk (Dry Cast Resin Option)

Cast resin transformers encapsulated in epoxy under high vacuum are completely flame-retardant, self-extinguishing, and non-pollutingβ€”ideal for indoor hospital and high-rise basements.

🌧️

Corrosion-Proof Hermetic Tank

Transformer tanks are fabricated from heavy-gauge mild steel, shot-blasted to SA 2.5, and coated with epoxy-polyurethane paint to survive harsh coastal and tropical weathering.

πŸ”

Comprehensive Safety Instrumentation

Equipped with Buchholz relays, magnetic oil gauges, pressure relief valves, and dual-contact temperature controllers wired to trip upstream VCBs immediately upon fault.

Certified Quality & Factory Testing Standards

⚑ IS 2026 / IS 1180 (Part-1) & IEC 60076

Every Transformers (Power Distribution Transformers) is manufactured under strict ISO 9001:2008 quality control protocols and subjected to comprehensive routine testing at our Kolkata facility before dispatch.

βœ” Measurement of winding resistance on all taps for HV and LV windings.
βœ” Voltage ratio, polarity check, and phase relationship (Dyn11 vector group verification).
βœ” No-load loss and excitation current measurement at rated frequency and nominal voltage.
βœ” Load loss and percentage impedance measurement at rated frequency and full load current.
βœ” Separate source power frequency voltage withstand test and induced over-voltage withstand test.
βœ” Insulation resistance measurement (Megger) and dielectric breakdown voltage (BDV) test on insulating oil.

Target Industrial Sectors & Deployment Scenarios

Engineered and tested for severe continuous operational duty across diverse sectors:

🏭 Heavy Industrial Substations & Steel Foundries 🏭 High-Rise Commercial Buildings & Residential Townships 🏭 Hospitals, Airports & Rail Transit Hubs 🏭 Renewable Solar & Wind Farms 🏭 Utility Electricity Distribution Grids 🏭 Chemical, Petrochemical & Textile Mills

Related Switchgears & Equipment

Explore complementary electrical power distribution and protection units manufactured by Moby.

Frequently Asked Questions

Authoritative engineering answers regarding voltage ratings, CPRI testing, custom SLD fabrication, and warranty for Transformers (Power Distribution Transformers).

What are the technical voltage and breaking ratings for MOBY Transformers (Power Distribution Transformers)? +

Primary Parameter Ratings: MOBY Transformers (Power Distribution Transformers) is engineered for rated voltage 100 kVA to 2000 kVA and rated normal current 11 kV / 22 kV / 33 kV. It is built to withstand prospective short-circuit breaking currents up to 40 kA for 3 seconds, fully adhering to national and international power engineering guidelines.

Is MOBY Transformers (Power Distribution Transformers) CPRI tested and certified? +

Certification & Type Testing: Yes, MOBY Transformers (Power Distribution Transformers) is IS 2026 / IS 1180 (Part-1) & IEC 60076. All switchgears undergo comprehensive type-testing at the Central Power Research Institute (CPRI) and are routine tested (high-voltage dielectric withstand, contact resistance, and operational timing) at our ISO 9001:2008 certified Kolkata manufacturing facility prior to customer dispatch.

Can this equipment be customized according to our single-line diagram (SLD)? +

Custom Engineering Capabilities: Yes, Moby Electrotech specializes in custom-engineered electrical switchgear systems. Our Kolkata engineering team customizes incoming/outgoing feeder arrangements, CT/PT ratios, numerical protection relays, busbar ratings, enclosure dimensions, and ingress protection (IP42 to IP55) to match your exact site layout and SLD.

What is the standard warranty and quotation timeline for Transformers (Power Distribution Transformers)? +

Commercial Terms & Warranty: All MOBY equipment carries an engineering equipment warranty of 12 months from commissioning or 18 months from delivery. Technical commercial quotations are typically provided within 24 to 48 hours following single-line diagram (SLD) review.

Request Technical Quote for Transformers (Power Distribution Transformers)

Our senior electrical engineering team will review your single-line diagram (SLD), system voltage, and breaking requirements to provide a competitive quotation within 24 hours.