Our Products

We manufacture and market the complete range of heavy-duty HT & LT switchgears, transformers, power factor correction panels, and automation units.

🔍
1 VCB Vacuum Circuit Breaker
HT Switchgear

1. VCB (VACUUM CIRCUIT BREAKER)

InstallationIndoor / Outdoor
Voltage6.6 KV / 12 KV / 36 KV
Current400A / 630A / 800A / 1250A
Options1 Incomer 2 Outgoing / Customized
2 LBS Load Break Switch
Switchgear

2. LBS (LOAD BREAK SWITCH)

InstallationIndoor / Outdoor
Voltage6.6 KV / 12 KV / 36 KV
MechanismQuick-make quick-break spring mechanism
3 APFC Panels
Power Quality

3. APFC PANELS

AUTOMATIC POWER FACTOR CORRECTION PANEL

Key Advantages:
  • Reducing Peak KW billing demand
  • Eliminating the power factor penalty
  • Achieving rebates for high power factor from electricity board
  • Increased System Capacity and Reduced System Losses in Electrical System
4 Power Control Centers with APFC
Combined Distribution

4. POWER CONTROL CENTERS WITH APFC

COMBINED INTEGRATED UNIT (PCC + APFC)

Key Advantages:
  • Low space consumption — single compact enclosure
  • Highly cost effective compared to dual standalone panels
  • Pre-engineered internal copper/aluminium busbar coupling
5 AMF Panels
Automation

5. AMF PANELS

AUTO-MAIN FAILURE PANELS

Key Advantages:
  • As soon as there is a power failure, generator is automatically turned ON (no loss of work)
  • Utilizing the full plant capacity without manual changeover lags
  • Higher efficiency and more productivity
6 MCC Panels Motor Control Centers
Motor Automation

6. MCC PANELS

MOTOR CONTROL CENTERS

FeedersDOL / Star-Delta / Soft Starter
EnclosureForm 3b / Form 4 Compartmentalized
ProtectionThermal Overload, Short-Circuit, Phase Reversal
7 Panels for Automation PLC Drives
Automation

7. PANELS FOR AUTOMATION

PLC / DRIVES PANELS

ControllerPLC / SCADA Integration
DrivesVFD (Variable Frequency Drives) / Soft Starters
ApplicationProcess plant automation, synchronization, pumping
8 Power Packs
Trip Protection

8. POWER PACKS

Application:
  • It stores energy for a short time for emergency trip of Breakers during electrical outages.
  • Guarantees positive tripping impulse when auxiliary supply fails.
9 Relay and Control Panel
Protection & Control

9. RELAY AND CONTROL PANEL

InstallationIndoor / Outdoor
Voltage Range6.6 KV to 110 KV
RelaysNumerical / Static / Electromechanical
10 Power Distribution Transformer
Transformers

10. TRANSFORMERS

POWER DISTRIBUTION TRANSFORMERS

CoolingOil type / Dry type
Tap ChangerWith OLTC / Without OLTC
Capacity100 KVA to 2000 KVA
MountingIndoor / Outdoor
11 Unitised Sub-Station
Packaged Substation

11. UNITISED SUB-STATION

VoltageUpto 12 KV
RatingUpto 1000 KVA
ModulesHT Ring Main / Breaker + Transformer + LT Distribution Panel
12 Outdoor Type CT and PT
Instrument Transformers

12. OUTDOOR TYPE CT AND PT

VoltageUpto 132 KV
CoolingOil Cooled Hermetically Sealed
Accuracy ClassMetering 0.2s / 0.5s • Protection 5P10 / 5P20
13 Outdoor Type CT-PT Metering Units
Metering

13. OUTDOOR CT-PT METERING UNITS

VoltageUpto 33 KV
ConfigurationCombined CT and PT oil-immersed tank
ComplianceState Electricity Board tariff metering standards
14 Cables All Types
Cables & Supplies

14. CABLES (ALL TYPES)

TypesHT XLPE / LT Armoured / Control / Flexible
ConductorAluminium / Copper
AccessoriesJointing kits, terminations, glands & lugs

Frequently Asked Procurement Questions

Expert engineering guidance on switchgear selection, voltage matching, APFC penalty elimination, and dispatch documentation.

How do I choose between a Vacuum Circuit Breaker (VCB) and a Load Break Switch (LBS)? +

VCBs are recommended for primary substation incoming/outgoing feeders where automatic short-circuit fault interruption (up to 40 kA) and rapid auto-reclosing duty are required. Load Break Switches (LBS) are ideal for distribution transformer switching, secondary substations, and ring main units where manual or motor-operated switching under normal load currents with HT fuse short-circuit protection is cost-effective.

Why should a commercial or industrial facility install an Automatic Power Factor Correction (APFC) Panel? +

APFC panels continuously monitor lagging reactive power (kVAR) and dynamically switch balanced capacitor stages via microprocessor relays to maintain power factor above 0.98. This eliminates electricity board low-power-factor penalties (WBSEDCL, CESC, Tata Power), reduces maximum kVA demand charges, mitigates transformer I²R heating losses, and earns utility power factor rebates.

What are the benefits of a Combined Unit PCC with APFC over separate panels? +

MOBY's Combined Unit PCC with APFC integrates primary busbars, main incoming Air Circuit Breaker (ACB), outgoing motor/distribution feeders, and capacitor bank stages into a single factory-coupled enclosure. This design saves up to 40% valuable substation footprint, eliminates inter-panel cabling and external busducts, and provides unified single-point testing.

What documentation and test reports are provided with every switchgear dispatch? +

Every dispatch from our Kolkata plant includes comprehensive Routine Test Certificates (dielectric insulation test, contact resistance CRM, breaker opening/closing timing), CPRI Type Test Report references, General Arrangement (GA) drawings, Single-Line Diagrams (SLD), schematic control wiring diagrams, and O&M instruction manuals.

What are the standard delivery lead times for custom-engineered panels and switchgears? +

Standard ratings (VCB panels up to 1250A, standard APFC banks) are typically manufactured and routine-tested within 3 to 5 weeks from drawing approval. Large custom-engineered Power Control Centers (PCC), 33kV switchgears, and unitised substations range from 6 to 10 weeks depending on component imports and client drawing sign-off.