1. VCB (VACUUM CIRCUIT BREAKER)
| Installation | Indoor / Outdoor |
| Voltage | 6.6 KV / 12 KV / 36 KV |
| Current | 400A / 630A / 800A / 1250A |
| Options | 1 Incomer 2 Outgoing / Customized |
2. LBS (LOAD BREAK SWITCH)
| Installation | Indoor / Outdoor |
| Voltage | 6.6 KV / 12 KV / 36 KV |
| Mechanism | Quick-make quick-break spring mechanism |
3. APFC PANELS
AUTOMATIC POWER FACTOR CORRECTION PANEL
- Reducing Peak KW billing demand
- Eliminating the power factor penalty
- Achieving rebates for high power factor from electricity board
- Increased System Capacity and Reduced System Losses in Electrical System
4. POWER CONTROL CENTERS WITH APFC
COMBINED INTEGRATED UNIT (PCC + APFC)
- Low space consumption — single compact enclosure
- Highly cost effective compared to dual standalone panels
- Pre-engineered internal copper/aluminium busbar coupling
5. AMF PANELS
AUTO-MAIN FAILURE PANELS
- As soon as there is a power failure, generator is automatically turned ON (no loss of work)
- Utilizing the full plant capacity without manual changeover lags
- Higher efficiency and more productivity
6. MCC PANELS
MOTOR CONTROL CENTERS
| Feeders | DOL / Star-Delta / Soft Starter |
| Enclosure | Form 3b / Form 4 Compartmentalized |
| Protection | Thermal Overload, Short-Circuit, Phase Reversal |
7. PANELS FOR AUTOMATION
PLC / DRIVES PANELS
| Controller | PLC / SCADA Integration |
| Drives | VFD (Variable Frequency Drives) / Soft Starters |
| Application | Process plant automation, synchronization, pumping |
8. POWER PACKS
- It stores energy for a short time for emergency trip of Breakers during electrical outages.
- Guarantees positive tripping impulse when auxiliary supply fails.
9. RELAY AND CONTROL PANEL
| Installation | Indoor / Outdoor |
| Voltage Range | 6.6 KV to 110 KV |
| Relays | Numerical / Static / Electromechanical |
10. TRANSFORMERS
POWER DISTRIBUTION TRANSFORMERS
| Cooling | Oil type / Dry type |
| Tap Changer | With OLTC / Without OLTC |
| Capacity | 100 KVA to 2000 KVA |
| Mounting | Indoor / Outdoor |
11. UNITISED SUB-STATION
| Voltage | Upto 12 KV |
| Rating | Upto 1000 KVA |
| Modules | HT Ring Main / Breaker + Transformer + LT Distribution Panel |
12. OUTDOOR TYPE CT AND PT
| Voltage | Upto 132 KV |
| Cooling | Oil Cooled Hermetically Sealed |
| Accuracy Class | Metering 0.2s / 0.5s • Protection 5P10 / 5P20 |
13. OUTDOOR CT-PT METERING UNITS
| Voltage | Upto 33 KV |
| Configuration | Combined CT and PT oil-immersed tank |
| Compliance | State Electricity Board tariff metering standards |
14. CABLES (ALL TYPES)
| Types | HT XLPE / LT Armoured / Control / Flexible |
| Conductor | Aluminium / Copper |
| Accessories | Jointing kits, terminations, glands & lugs |
Frequently Asked Procurement Questions
Expert engineering guidance on switchgear selection, voltage matching, APFC penalty elimination, and dispatch documentation.
How do I choose between a Vacuum Circuit Breaker (VCB) and a Load Break Switch (LBS)? +
VCBs are recommended for primary substation incoming/outgoing feeders where automatic short-circuit fault interruption (up to 40 kA) and rapid auto-reclosing duty are required. Load Break Switches (LBS) are ideal for distribution transformer switching, secondary substations, and ring main units where manual or motor-operated switching under normal load currents with HT fuse short-circuit protection is cost-effective.
Why should a commercial or industrial facility install an Automatic Power Factor Correction (APFC) Panel? +
APFC panels continuously monitor lagging reactive power (kVAR) and dynamically switch balanced capacitor stages via microprocessor relays to maintain power factor above 0.98. This eliminates electricity board low-power-factor penalties (WBSEDCL, CESC, Tata Power), reduces maximum kVA demand charges, mitigates transformer I²R heating losses, and earns utility power factor rebates.
What are the benefits of a Combined Unit PCC with APFC over separate panels? +
MOBY's Combined Unit PCC with APFC integrates primary busbars, main incoming Air Circuit Breaker (ACB), outgoing motor/distribution feeders, and capacitor bank stages into a single factory-coupled enclosure. This design saves up to 40% valuable substation footprint, eliminates inter-panel cabling and external busducts, and provides unified single-point testing.
What documentation and test reports are provided with every switchgear dispatch? +
Every dispatch from our Kolkata plant includes comprehensive Routine Test Certificates (dielectric insulation test, contact resistance CRM, breaker opening/closing timing), CPRI Type Test Report references, General Arrangement (GA) drawings, Single-Line Diagrams (SLD), schematic control wiring diagrams, and O&M instruction manuals.
What are the standard delivery lead times for custom-engineered panels and switchgears? +
Standard ratings (VCB panels up to 1250A, standard APFC banks) are typically manufactured and routine-tested within 3 to 5 weeks from drawing approval. Large custom-engineered Power Control Centers (PCC), 33kV switchgears, and unitised substations range from 6 to 10 weeks depending on component imports and client drawing sign-off.