MOBY In Power Protection - Official Logo
MOBY ELECTROTECH • IN POWER PROTECTION
⚑ AN ISO 9001:2008 CERTIFIED COMPANY πŸ“ 300 Roy Bahadur Road, Kolkata 700053
πŸ“ž 9830143071 / 9830634218 βœ‰οΈ [email protected]
Grid Substation Protection Suite

Relay and Control Panel (CRP)

Transmission & Substation Numerical Protection, Control & SCADA Automation

MOBY Relay and Control Panels (CRP) are engineered for high-voltage transmission and distribution substations from 6.6 kV up to 132 kV. Integrating cutting-edge numerical multifunction protection relays, active mimic control diagrams, breaker status indicators, and Class 0.2S digital revenue metering, our panels protect high-capital transformers, busbars, and transmission lines while ensuring seamless IEC 61850 substation automation.

System Voltage Range 6.6 kV to 132 kV Substations
Panel Architecture Simplex / Duplex / Swing-Frame
Relay Technology Microprocessor Numerical Multifunction
Communication Protocol IEC 61850 / Modbus RTU / Profibus
βœ“ 100% Factory Routine Tested βœ“ Custom Ratings Built-to-Order βœ“ ISO 9001:2008 Certified

Comprehensive Technical Specifications

Detailed parameter ratings, insulation limits, standards compliance, and fabrication tolerances engineered for Relay and Control Panel (CRP).

Technical Parameter Engineering Specification Compliance Standard / Condition
πŸ”· Electrical System & Protection Architecture
Nominal Substation Voltage 6.6 kV / 11 kV / 33 kV / 66 kV / 132 kV IS / IEC Standard
Auxiliary DC Supply Voltage 24V / 30V / 110V / 220V DC from station battery Station DC Bus
Auxiliary AC Supply Voltage 230V AC Β± 10%, 50 Hz for panel illumination & heaters Station AC Bus
Numerical Protection Functions Overcurrent & Earth Fault (50/51/51N), Transformer Differential (87T), Distance Protection (21), Under-Frequency (81), Master Trip (86) IEEE C37.2 Device Codes
Secondary CT Inputs 1A or 5A rated (100A 1s thermal withstand) IS 2705 / IEC 60044
Secondary PT Inputs 110V AC (Phase-to-Phase) / 63.5V AC (Phase-to-Neutral) IS 3156 / IEC 60044
πŸ”· Control, Mimic & Metering Elements
Breaker Control Switch Trip-Neutral-Close (T-N-C) pistol-grip heavy duty rotary switch Spring Return to Neutral
Local / Remote Selector Key-operated lockable Local / Remote / Supervisory selector switch Security Interlocked
Active Mimic Diagram Engraved acrylic or aluminium mimic diagram with active dual-color LED indicators Real-Time Bus Mimic
Energy & Tariff Metering Class 0.2S / 0.5S Multi-Function Digital Energy Meter with optical port IS 14697 / IEC 62053
Alarm Annunciator 12 to 24-Window microprocessor alarm annunciator with Test/Accept/Reset pushbuttons High-Audibility Hooter
Communication Bus Dual redundant optical fiber Ethernet ports supporting IEC 61850 Station Bus & Goose messaging Substation Automation Ready
πŸ”· Mechanical & Constructional Data
Panel Architecture Style Simplex (Front access), Duplex (Corridor walk-through), or Swing-Frame Custom Grid Layout
Sheet Steel Fabrication 2.0 mm CRCA framework and doors / 3.0 mm bottom cable gland plates Vermin-Proof
Surface Coating 7-Tank Pretreatment, Powder Coated RAL 7032 / 7035 with 80+ microns thickness Corrosion Resistant
Degree of Enclosure Protection IP52 (Vermin & dust proof with neoprene foam gasketing) IS/IEC 60529
Anti-Condensation Protection Thermostatically controlled space heaters with humidistat & door-operated CFL/LED lamps Moisture Prevention

Key Engineering & Operational Features

Why electrical consultants, industrial plants, and utility engineers specify MOBY Relay and Control Panel (CRP).

🧠

Advanced Numerical Protection

Compatible with world-class numerical relays (ABB Relion, Siemens Reyrolle/Siprotec, Schneider Micom) providing millisecond fault clearance and comprehensive fault recording.

🌐

IEC 61850 Substation Automation

Fully interoperable with modern grid automation architectures via IEC 61850 protocol, enabling high-speed GOOSE peer-to-peer tripping and remote SCADA monitoring.

πŸ—ΊοΈ

Intuitive Active Mimic Diagrams

Clear, color-coded mimic busbars with semaphore indicators provide operators with immediate situational awareness of breaker and isolator positions before switching.

πŸ“Š

Class 0.2S High-Accuracy Metering

Integrated multi-function revenue meters capture active, reactive, and apparent energy, power factor, harmonics, and load profile records with bidirectional capability.

🚨

Comprehensive Fault Annunciation

Microprocessor annunciator flashes prioritized visual alerts for transformer buchholz alarms, winding over-temperature, bus earth faults, and DC battery failure.

πŸšͺ

Vermin-Proof & Heavy-Duty Enclosure

Built with dust-sealed gaskets, fine wire-mesh breathers, and vermin-proof bottom plates to prevent insect intrusion into sensitive digital circuitry.

Certified Quality & Factory Testing Standards

⚑ IS 8623 / IEC 60255 & IEC 61850

Every Relay and Control Panel (CRP) is manufactured under strict ISO 9001:2008 quality control protocols and subjected to comprehensive routine testing at our Kolkata facility before dispatch.

βœ” Complete secondary current and voltage injection testing using Omicron / calibrated secondary injection test kit.
βœ” Functional trip matrix verification: testing every relay contact against breaker trip coils and annunciator alarms.
βœ” High voltage power frequency dielectric test at 2.0 kV AC for 1 minute on all CT, PT, and auxiliary circuits.
βœ” Insulation resistance measurement before and after HV test exceeding 50 Megaohms at 1000V DC.
βœ” IEC 61850 communication protocol conformance check and GOOSE message timing latency verification.

Target Industrial Sectors & Deployment Scenarios

Engineered and tested for severe continuous operational duty across diverse sectors:

🏭 132kV / 66kV / 33kV State Transmission Substations 🏭 Thermal, Hydro & Solar Grid Interconnection Substations 🏭 Captive Power Plant Generation Substations 🏭 Large Steel, Metal & Heavy Chemical Complexes 🏭 Metro Rail & Railway Traction Traction Substations 🏭 High-Voltage Industrial Distribution Networks

Related Switchgears & Equipment

Explore complementary electrical power distribution and protection units manufactured by Moby.

Frequently Asked Questions

Authoritative engineering answers regarding voltage ratings, CPRI testing, custom SLD fabrication, and warranty for Relay and Control Panel (CRP).

What are the technical voltage and breaking ratings for MOBY Relay and Control Panel (CRP)? +

Primary Parameter Ratings: MOBY Relay and Control Panel (CRP) is engineered for rated voltage 6.6 kV to 132 kV Substations and rated normal current Simplex / Duplex / Swing-Frame. It is built to withstand prospective short-circuit breaking currents up to 40 kA for 3 seconds, fully adhering to national and international power engineering guidelines.

Is MOBY Relay and Control Panel (CRP) CPRI tested and certified? +

Certification & Type Testing: Yes, MOBY Relay and Control Panel (CRP) is IS 8623 / IEC 60255 & IEC 61850. All switchgears undergo comprehensive type-testing at the Central Power Research Institute (CPRI) and are routine tested (high-voltage dielectric withstand, contact resistance, and operational timing) at our ISO 9001:2008 certified Kolkata manufacturing facility prior to customer dispatch.

Can this equipment be customized according to our single-line diagram (SLD)? +

Custom Engineering Capabilities: Yes, Moby Electrotech specializes in custom-engineered electrical switchgear systems. Our Kolkata engineering team customizes incoming/outgoing feeder arrangements, CT/PT ratios, numerical protection relays, busbar ratings, enclosure dimensions, and ingress protection (IP42 to IP55) to match your exact site layout and SLD.

What is the standard warranty and quotation timeline for Relay and Control Panel (CRP)? +

Commercial Terms & Warranty: All MOBY equipment carries an engineering equipment warranty of 12 months from commissioning or 18 months from delivery. Technical commercial quotations are typically provided within 24 to 48 hours following single-line diagram (SLD) review.

Request Technical Quote for Relay and Control Panel (CRP)

Our senior electrical engineering team will review your single-line diagram (SLD), system voltage, and breaking requirements to provide a competitive quotation within 24 hours.

⚑ Direct Factory Response • Confidential Single-Line Diagram Reviews